Residual Current Protection Device(RCCB)

  • SL2-63A RCD circuit breaker (Residual Current Breaker)
  • SL2-63A RCD circuit breaker (Residual Current Breaker)
SL2-63A RCD circuit breaker (Residual Current Breaker)SL2-63A RCD circuit breaker (Residual Current Breaker)

SL2-63A RCD circuit breaker (Residual Current Breaker)

  • Product description: SL2-63A 2P RCD circuit breaker , China Best quality factory
  • INQUIRY

The SL2-63 RCD circuit breaker(RCCB) is suitable for AC 50 Hz / 60 Hz, the rated voltage is 230 V to 400 V, and the rated current is from 63 A to 100 A. when someone is electrocuted or the leakage current of the power grid exceeds the specified value,the RCD circuit breaker(RCCB) can quickly and automatically cut off the fault power supply in a very short time Indirectly guarantee the safety of personal .

 SL2-63 RCD circuit breaker(RCCB) Normal working conditions

1. Ambient temperature: - 5 ℃ ~ + 40 ℃. The average temperature in 24h does not exceed + 35 ℃.

2. Altitude: no more than 2000m.

3. Pollution level: 3.

4. Installation conditions:

a. Installation type and type: the installation category is II and III, and the installation type is rail installation;

b. Generally, the circuit breaker should be installed vertically, with the handle upward as the power on position;

c. There should be no significant impact and vibration, corrosive and explosive gas at the installation site;

d. DIN standard rail (TH35-7.5 type) is adopted;

e. The external magnetic field of the installation site should not exceed 5 times of the geomagnetic field in any direction;

f. Wiring mode: screw down the wiring.


 SL2-63 RCD circuit breaker(RCCB) Specification


Type Standard IEC/EN 61008-1
Electrical features Leakage type
Electromagnetic type
Rated current In A 16, 25, 32,40, 50, 63, 80,100
Type (wave form of the earth leakage sensed)
A, AC
Poles P 2,4
Rated voltage Ue V 240/415
Insulation voltage Ui V 500
Rated frequency Hz 50/60
Rated breaking capacity Inc=Ic A 4500,6000
SCPD fuse A 6000
Rated impulse withstand voltage (1.2/50) Uimp V 6000
Dielectric test voltage at ind. Freq, for lmin kV 2.5
Rated sensitivity I?n A 0.03, 0.1, 03
Rated residual making and breaking capacity Im A 500(In<40A); 630(In >40A)
Pollution degree
2
Mechanical features Electrical life t 4000
Mechanical life t 8000
Protection degree
IP20
Storage temperature °C 25~+70
Ambient temperature (with daily averages35°C) °C -5-+40
Installation Terminal connection type
Cable/U-type bar/Pin-type busbar
Terminal size top / bottom for cable mm2 25
AWG 18-3
Terminal size top / bottom for busbar mm2 25
AWG 18-3
Tightening torque N*m 2.5
In-Ibs 18
Mounting On DIN rail EN 60715(35mm)by means of fast clip device
Connection
From top and bottom